Code-compliant passive fire protection for structural steel, concrete, and building assemblies.
Fireproofing is the application of fire-resistive materials to structural elements to maintain their load-bearing capacity during a fire event. Applied to steel beams, columns, decks, and concrete surfaces, fireproofing buys critical time for evacuation and limits structural collapse. ApexSeal NY is a certified fireproofing contractor serving commercial, industrial, and institutional projects across NY, NJ, and CT — delivering fully code-compliant, inspected, and documented installations.
We review the structural drawings and determine the required fire-resistance ratings (1-hour, 2-hour, 3-hour, or 4-hour) for each element based on IBC occupancy and construction type.
We select UL-listed fireproofing assemblies that match the structural member sizes, required ratings, and aesthetic requirements of the project.
Steel surfaces are cleaned of oil, dirt, and loose mill scale. Primer compatibility is verified. Masking protects adjacent finished surfaces.
Spray-applied fireproofing (SFRM) or intumescent coatings are applied in controlled passes to achieve the specified thickness for the required fire rating.
We perform systematic thickness measurements using calibrated pins and document results. Minimum thickness must be met at every measurement point.
We coordinate with the special inspector and provide all documentation — product data sheets, thickness logs, and UL assembly references — for the project record.
Spray-applied fire-resistive material (SFRM) — commonly called "spray fireproofing" — is a cementitious or gypsum-based material applied in thick coats. It is cost-effective for concealed steel. Intumescent coatings are thin-film coatings that expand when exposed to heat, providing fire protection with a smooth, paintable finish suitable for exposed architectural steel.
We install assemblies rated from 1 hour to 4 hours depending on the structural element, building occupancy, and code requirements. The required rating is determined by the building code and structural engineer of record.
Requirements depend on building height, occupancy type, and construction classification under the IBC. Most commercial steel-framed buildings require fireproofing on primary structural members. We review the code requirements for your specific project.
Yes. We perform fireproofing repairs and touch-ups on existing buildings where the material has been damaged by mechanical impact, water, or renovation work. Repairs must match the original UL assembly.
Free estimates. Fast scheduling. No pressure.